Diesel Generator Set XG-200GF
Prime Output:200KW/250KVA
Rated Current:656(A)
Rated Frequency:60(Hz)
Rated Voltage:110/220(V)
Engine:DCEC CUMMINS 4BTA3.9-G11
Availability: | |
---|---|
Quantity: | |
XG-200GF
Star
SINOCTM is located in Ji′Nan city, Shandong province, SINOCTM aims to provide the project solutions with best cost performance to customers from China and abroad. Our main business are construction solutions consultancy, equipments supply, technical instruction, parts supply, service & training, logistic support and etc, providing the steward type service.
We cooperate with SINOTRUK, FOTON, SDLG, XCMG, Liugong, Shantui, Sany, Zoomlion, Hongda and other premium brands to provide tailored project solutions to your specific needs. We can help you to avoid long-time communication with different suppliers, which will save you time and cost. As to after market, with many years′ experience in the industry and long-term partnership with the suppliers, we do provide timely after market with lower cost and higher availability.
Diesel Generator Set Data XG-200GF/250KVA Cummins | |
Overall Size | Weight |
2550(mm)*960(mm)*1650(mm) | 2000(kg) |
Set Model: | XG-200GF |
Prime Output: | 200KW/250KVA |
Rated Current: | 656(A) |
Rated Frequency: | 60(Hz) |
Start-up time: | 5~6(s) |
Power Factor: | 0.8(Lag) |
Rated Voltage: | 110/220(V) |
Standard Features | |
Engine: Cummins 6LTAA8.9-G2;Radiator 50℃ max;Fans are driven by belt, with safety guard; 24V charge alternator;Dry type air filter, fuel filter, oil filter;Alternator: single bearing alternator; IP23, insulation class H/H;Main line circuit breaker;Standard control panel; Absorber;Muffler;User manual; | |
Diesel Engine Data | |
Manufacturer: | Cummins |
Model: | 6LTAA8.9-G2 |
Engine Power: | 258KW |
Rated Speed: | 1800(r/min) |
Cycle: | 4 stroke |
Cylinder Arrangement: | 6 in line |
Displacement: | 8.9L |
Bore and Stroke: | 114*145(mm) |
Compression Ratio: | 16.5:1 |
Governor Type: | Electronic |
Start battery voltage: | 24V DC |
Air Intake System | |
Air Intake System: | Turbo, Water/Air Cooling |
Max Intake Restriction: | 6.25kPa |
Burning Capacity: | 7.9m3/min |
Air Flow: | 158m3/min |
Exhaust System | |
Exhaust Gas Flow: | 14.8m3/min |
Exhaust Temperature: | 557℃ |
Max Back Pressure: | 10kPa |
Fuel System | |
Fuel System: | PT type fuel pump |
100%( Prime Power) Load: | 190g/kwh |
Oil System | |
Oil Capacity: | 16.4L |
Oil Consumption: | ≤0.4g/kw·h |
Min Oil Pressure at Rated RPM: | 350kPa |
Cooling System | |
Cooling Way: | Water-cooled |
Total Coolant Capacity: | 27L |
Max Water Temperature: | 82-93℃ |
Thermostat: | 104℃ |
Alternator Data | |
Manufacturer: | Stamford |
Model: | UCD 274H |
Excitation Mode: | Brushless and self- exciting |
Number of phase and Access Act: | 3-phase 4-wire |
Connecting Type: | “Y” type connecting |
Alternator Capacity: | 255kVA |
Alternator Efficiency: | 95% |
Overload: | (PRP)110% load can run 1h /12h |
Protection Level: | IP23 |
Insulation Class, Temperature Rise: | H/H |
TIF Telephone Influence Factor (TIF): | <50 |
THF: | <2% |
Voltage Regulation, Steady State: | ≤±1% |
Air Cooling Flow: | 2.18m3/s |
Genset Electrical Performance | |
Voltage Regulation: | ≥±5% |
Voltage Regulation, Stead State: | ≤±1% |
Sudden Voltage Warp (100% Sudden Reduce): | ≤+25% |
Sudden Voltage Warp (Sudden Increase): | ≤-20% |
Voltage Stable Time (100% Sudden Reduce): | ≤6S |
Voltage Stable Time (Sudden Increase): | ≤6S |
Frequency Regulation, Stead State: | ≤5% |
Frequency Waving: | ≤1.5% |
Sudden Frequency Warp (100% Sudden Reduce): | ≤+12% |
Sudden Frequency Warp (Sudden Increase): | ≤-10% |
Frequency Recovery Time(100%Sudden Reduce): | ≤5S |
Frequency Recovery Time(Sudden Increase): | ≤5S |
The manufacturer reserves the right of technical alteration /change for better improvement without prior notice |
Our low noise gensets (Silent gensets) use shock insulation, sound insulation, and sound absorbing and so on noise reduction measures
tomake the noise indexes decreased significantly. The low noise GFD series power station are individed into fixed and mobile types.
The noise level can reach below 80 dB(A).
This kind of power station has good mobility, strong adaptability and rapid power supply. It is suitable to be used in densely populated areas or where the
environmental noise is strictly required. For example, studio, star-rated hotels, office building, scientific research institution, hospital, and universities and colleges, etc.
Characteristics of Our low noise diesel generators
1. Low noise, overall compact structure, little space occupation;
2. The box body is detachable structure, it is made of steel plate, and the surface is coated with high performance antirust paint; Meanwhile,
it is with noise reduction
and rainproof function.
3. The inside of the boby adopts multilayer barrier impedance mismatch noise elimination structure and built in large impedance silencer.
4. The box body structure design is reasonable; A large capacity oil tank is arranged inside the body; At the same time, two inspection doors
are arranged at the left
and right side of the body in order to facilitate the genset troubleshooting.
5. At the same time, the observation window and the emergency stop button are set on the box body so as to observe the running state of the genset as well as stop
the machine at the fastest speed in case of emergency so as to avoid damage to the genset.
6. Bottom fuel tank for 8-12 hours operation